    TI-CMX10-DL Full Wave Capture Ultrasonic Thickness Gauge

    Full wave capture ultrasonic thickness gauge for advanced corrosion and precision measurement

    The TI-CMX10-DL combines corrosion thickness measurement and high-resolution precision measurement in one advanced ultrasonic gauge. It supports Pulse-Echo, Echo-Echo, Echo-Echo Verify and dedicated second-layer modes, with A-Scan and B-Scan recording for detailed waveform analysis and inspection review.

    Time Corrected Gain (TCG), Backwall Echo Attenuation (BEA), adjustable filtering and waveform comparison help evaluate weak or complex signals on corroded, attenuative or multi-layer materials. Single-element delay-line probes can also be used for precise measurement of thin components, while compatible dual-element probes are suited to corrosion and general wall-thickness inspection.

    The colour touchscreen can be used together with the physical keypad, and inspection data can be stored internally or on an external memory card. USB and Bluetooth® LE provide data connectivity, while remote screen viewing and control support collaborative inspection and review.

    Transducer sold separately: the TI-CMX10-DL is supplied without a transducer because probe selection depends on the material, thickness range and inspection method. Compatible options include dual-element corrosion probes, coating-enabled probes, single-element contact and delay-line probes, and angular probes for prove-up applications.

    € 4.638,00
    Order now
    • Corrosion and precision ultrasonic thickness measurement with dual- and single-element transducers
    • Pulse-Echo, Echo-Echo, Echo-Echo Verify and dedicated second-layer measurement modes
    • A-Scan and B-Scan recording for waveform review, material profiling and depth analysis
    • Records A-Scan waveforms for up to 10 seconds at 20 A-Scans per second
    • Time Corrected Gain (TCG) with ramp or curve correction using up to 16 points
    • Backwall Echo Attenuation (BEA), adjustable filtering and signal averaging for difficult materials and weak echoes
    • Compatible with single-element delay-line probes for high-resolution measurement of thin components
    • Stores up to 20,000 A-Scans in 128 MB internal memory or approximately 5 million using a 32 GB external memory card
    • Colour touchscreen and physical keypad with USB, Bluetooth® LE and remote screen viewing/control
    • TI-CMX10-DL ultrasonic thickness gauge
    • Power supply with UK, EU and US adapters
    • Rechargeable Smart Battery Pack, Li-Ion 10.8 V, 3.35 Ah, 36.2 Wh
    • Ultrasonic couplant
    • Hand strap with extension pieces
    • Screen protector
    • Transit case
    • USB cable
    • User guide

    Transducer is not included and must be ordered separately.

    Measurement Modes and RangesPulse-Echo (PE): 0.18–1480 mm (0.007–58.3 in), depending on transducer
    Echo-Echo / ThruPaint™ (EE): 0.18–592 mm (0.007–23.3 in), depending on transducer
    Echo-Echo Verify (EEV): 0.18–296 mm (0.007–11.7 in), depending on transducer
    2nd Layer (PE2): 0.18–1480 mm (0.007–58.3 in), depending on transducer
    2nd Layer ThruPaint™ (EE2): 0.18–592 mm (0.007–23.3 in), depending on transducer
    Measurement Accuracy±0.01 mm or ±1% of reading, whichever is greater, with 5 MHz 1/4 in transducer on steel
    Measurement Resolution0.001 mm (0.0001 in)
    Velocity Calibration Range200–20,000 m/s (0.0079–0.7874 in/µs)
    Transducer Types and Frequency RangeDual-element contact, single-element contact, single-element delay-line and angular prove-up transducers
    Frequency range: 1–20 MHz
    Probe Connections2 × LEMO 00 sockets (Tx/Rx) and 1 × ODU Smart Port
    Memory and Storage128 MB internal storage; supports external memory cards up to 32 GB
    Data OutputUSB and Bluetooth® LE
    Display800 × 480 pixel colour graphical TFT touchscreen
    Power Supply and BatteryRechargeable Li-Ion Smart Battery Pack or mains power supply
    Battery: Li-Ion, 10.8 V, 3.35 Ah, 36.2 Wh
    Battery Life9–15 hours, depending on use
    Operating Temperature−10 to 50 °C
    Ingress ProtectionEquivalent to IP65 for the gauge
    Dimensions180 × 105 × 50 mm
    Weight872 g including battery
    Warranty1 year limited warranty
    Design StandardDesigned for EN 15317

    Order Now

    Products
    Item Product Price  Quantity Action
    140894TI-CMX10-DL Full Wave Capture Thickness Gauge € 4.638,00
    Accessories
    Item Product Price  Quantity Action
    130284T-104-0000 1 MHz Probe 1/2" for composites, thick plastics, rubber € 389,00
    126334T-102-1000 2.25 MHz Probe 1/4" € 378,00
    130496T-104-1000 1/2 inch 2.25 MHz Transd. for Cast Iron/Plastics (107) € 389,00
    137577T-101-2700 5 MHz Dual Element Transducer - 3/16 inch € 423,00
    126312T-102-2700 5 MHz Dual Element Transducer - 1/4 inch € 423,00
    133629T-104-2700 - 1/2" 5MHz Dual Element Hi Damped Transducer € 440,00
    140273T-101-3700 7,5 MHz Dual Element Transducer - 3/16 inch € 423,00
    135499T-102-3700 7.5 MHz MMX Probe 1/4 inch € 423,00

    All prices shown exclude VAT and shipping costs.
    Availability:
    Available: 1 - 3 days ,
    Delivery time: 1 - 3 weeks ,
    special order request

    We, Checkline Europe B.V., would like to use cookies and similar technologies to keep this site working properly, to understand how it is used, and to measure and improve our advertising. This requires your consent. By clicking "Accept analytics & advertising cookies" you agree to our use of cookies and similar technologies for analytics and advertising, including sharing personal data with Google for the measurement and personalisation of ads. If you would rather not, click "Reject analytics & advertising cookies" — we will then use only the cookies that are strictly necessary for the site to function. You can change your choice at any time on our cookie policy page. This banner will remain until you choose. Privacy policy
    Cookie Settings