NE214 Multifunctional Counter with two presets


Made in GermanyIVO multifunctional counter with two presets. Can be used in a wide variety of applications. Can be programmed as preselection counter, time counter, totalizer with divisor Time Meter and more.

Block diagram
Pin assignment

Features
  • Main counter with two presets, impulse signal time can be programmed (0.01...99.99 s)
  • Start value can be programmed
  • Interface RS485, RS422, RS232
  • Batch counter with multiplier (1-999)
  • Scaling can be programmed 0.0001...9999.99
  • Preselection mode can be programed:
    - Progressive, Principal preselection
    - Parallel comparison
    - Trailing preselection

Dimensions
Dimensions Electronic Counters NE214


Specifications
Display:
7-segment LED-display
6-digit dis. of real value, 14 mm high
Decimal point can be programmed
Suppression of leading zero
Operation, keypad:
Front membrane w. short-stroke keys
Front dimensions
DIN housing, 96 x 48 mm
Mounting:
Front installation
Fastening:
Clamping frame
Weight:
Version AC: ca. 350 g
Version DC: ca. 250 g
Type of connection:
Plug-in screw terminals
Grid 5.08 mm / 3.81 mm
Core cross-section:
Max. 1.5 mm2
Housing material:
Polycarbonate black, UL 94V-0
Membrane material:
Polyester
Supply voltage:
Choice of two voltages via switch on device. When supplied, always higher voltage adjusted.
115 / 230 VAC ±10 % (50 / 60 Hz)
24 / 48 VAC ±10 % (50 / 60 Hz)
24 VDC ±10 %, 5 % residual ripple
Power consumption:
7 VA, 5 W
Sensor supply:
12...26 VDC / max. 100 mA
Signal inputs:
Comparator inputs
PNP, NPN, Sinus or Namur
Without EX-protection
Input resistance ca. 3 kOhm
Voltage level 4...40 V
Input counting rate:
Can be programmed to 3 Hz, 25 Hz, 10 kHz
Control inputs:
2 control inputs for reset, stop, hold, print, etc.
Signal outputs:
Can be programmed as momentary or permanent signals
Impulse time can be programmed 0.01...9.99 s, tolerance: +0,01 s
Relay signal outputs:
2 floating center-zero relays
Internal spark suppression
Max. switching voltage 250 VAC
Max. switching power 1 A
Max. switching capacity 150 VA / 30 W
Electronic signal outputs:
Optocoupler
Max. switching voltage +40 V
Max. switchng power 15 mA
Max. residual voltage < 1 V
Analog output:
0(2)...10 V, 0(4)...20 mA
Offset as well as upper and lower analog limits can be programmed at the front
Data storage:
> 10 years via EEPROM
Counting mode of signal inputs A / B:
UP / DOWN, A - B, A + B, A 90° B x1, A 90° B x2, A 90° B x4
Ambient temperature:
0...+50 °C
Storage temperature:
-20...+70 °C
Relative humidity:
Max. relative humidity 80 %, at 25 °C, non-condensing
Protection:
Front IP 65 to DIN 40050
General rating:
EN 61010 Part 1
- Protection class II
- Overvoltage protection categ. II
- Contamination factor 2
Interference immunity:
EN 50082-2
Emitted interference:
EN 50081-1

Model Selector

Downloads

Buy Now
Products

Product name
Price
Quantity
NE214.012AX01 Multifunctional Counter
€ 406,80 
NE214.013AX01 Multifunctional Counter
€ 390,45 
NE214.022AX01 Multifunctional Counter
€ 495,30 
All mentioned prices are excluding VAT & excluding shipment costs.
Availability: Available , preorder 1-2 weeks , special order, request
If the desired model is not shown in the list of prices, price is on request

We Checkline Europe B.V. would like to use cookies and similar technologies in order to optimize your shopping experience and this requires your consent. By clicking on the "Accept cookies" button you agree to our use of cookies and similar technologies. If you do not agree, you can refuse the use or customize settings for the respective cookies by clicking on the button "Cookie Settings".You also have the possibility to specify that only certain cookies, which we use on our website should be activated. This banner will be displayed until you have selected your cookie preferences. If you decide against the use of cookies, we will not use cookies nor similar technologies, except those that are essential for the proper functioning of the website. Click here for our privacy policy