Show all products
Contact
Contact Us
Checkline Europe
Chat function is not available since you have not allowed us to use tracking cookies.
Click on an image for a larger image
DX2-EDM, Analog Tension Meters
DX2-EDM, Analog Tension Meters
DX2-EDM, Analog Tension Meters
DX2-EDM, Analog Tension Meters
DX2-EDM, Analog Tension Meters

DX2-EDM Wire EDM Tension Meter


Made in GermanyManufactures of wire-EDM machines recommend checking the erosion wire tension once a week. Depending on the machine type as well as the wire material and diameter, the measured tension should lie between 50 and 3000 g.

The correct erosion wire tension reduces wire oscillation and guarantees a pinpoint accuracy of your machines. Always check the tension in calibration mode on the moving wire. Make sure the generator is switched off for the tension check.

Features
  • Easy to operate and read analog scale
  • Special finger support located on the rear side reduces the effort to move the outer roller assembly
  • Ball-bearing mounted, V-grooved guide rollers
  • Roller shifting mechanism ensure easy acquisition of the running material
  • Everything in operator's view:
    - the guide rollers
    - the measured material
    - the readings
  • Each instrument is individually calibrated for highest accuracy
  • Rugged aluminium housing
  • Certificate of Compliance with the order 2.1 according DIN EN 10204 is included
  • Optionally available: Inspection Certificate 3.1 according DIN EN 10204 with calibration report

Dimensions
Dimensions Analog Tension Meters DX2-EDM


Dial Faces

Dial faces
Dial faces


Tension Ranges
ModelRanges cN Measuring Head SCHMIDT Calibration Material Thickness Compensator  
DX2-2000-EDM 50-2000 91PA: 0.30 mm Øno 
DX2-3000-EDM 100-3000 91PA: 0.30 mm Øno 
DX2-4000-EDM 200-4000 116PA: 0.30 mm Øyes 
Other tension ranges and measuring head widths available on request.
Other units of measure available, such as g.
* Depending on model, either width of wire guide or outer distance between outside guide rollers
** Suitable for 95% of applications - PA = Polyamide Monofilament

Special calibration using customer supplied samples is recommended, if process material differs significantly from the SCHMIDT calibration material in diameter, rigidity or shape. For this purpose a material sample of about 5 m should be supplied.

Specifications
Calibration:
According to SCHMIDT factory procedure
Accuracy:
±1% full scale or ±1 graduation on scale
Scale diameter:
41 mm
Temperature range:
8 - 45ºC
Air humidity:
85% RH, max.
Housing material:
Die-cast aluminium
Housing dimensions:
188 x 85 x 45 mm (LxWxH)
Weight, net (gross):
approx. 470 g (1000 g)
Rollers:
Material : Hardcoated aluminum
Diameter: 12 mm

We Checkline Europe B.V. would like to use cookies and similar technologies in order to optimize your shopping experience and this requires your consent. By clicking on the "Accept cookies" button you agree to our use of cookies and similar technologies. If you do not agree, you can refuse the use or customize settings for the respective cookies by clicking on the button "Cookie Settings".You also have the possibility to specify that only certain cookies, which we use on our website should be activated. This banner will be displayed until you have selected your cookie preferences. If you decide against the use of cookies, we will not use cookies nor similar technologies, except those that are essential for the proper functioning of the website. Click here for our privacy policy