| Gauge versions: |
DCF-3000PRO: for measurements on iron/steel DCN-3000PRO: for measurements on non-ferrous metals DCFN-3000PRO: for measurements on iron/steel and non-ferrous metals DCFN-3000PRO-90: for tube ID measurements on iron/steel and non-ferrous metals DCF-3000PRO-F10: for measurements on iron/steel up to 10mm |
| Measuring principle: |
Magnetic induction method (F-version); Eddy current method (N-version) |
| Measuring range: |
3000PRO & 3000PRO-FN90: 0 - 1500 µm 3000PRO-F10: 0 - 10,000 µm |
| Tolerance: |
± (0.7 µm/0.04 mils + 1% of reading) |
| Resolution: |
Refer To Table Above |
| Display: |
4-digit display (digit height 10 mm/0.4”) and 32 alphanumerical characters; switchable backlight |
| Minimum measurement area: |
5 mm x 5mm (0.2” x 0.2”) |
| Minimum curvature radius: |
convex 2mm (0.08”) concave 5mm (0.2”) |
| Minimum substrate thickness: |
0.2mm (8 mils) for F-version 50 µm (2 mils) for N-version |
| Calibration methods: |
- Factory calibration: no calibration required for standard applications - Zeroing (1-point calibration): measurements on small geometries - Zeroing and foil calibration (2-point calibration): increased measuring accuracy - Two-foil calibration: especially for rough, sand-blasted surfaces - CTC: calibration on coated object if zeroing is not possible - Zero offset: addition/subtraction of a constant value to/from the reading |
| Limit values: |
Selectable; optical and acoustic signal if limit value is exceeded |
| Scan mode: |
For continuous measurements; for the quick recognition of coating thickness variations; with permanent display of minimum and maximum reading |
| Statistics: |
Single-value statistics: n, avarage x, s, kvar, min, max, cp, cpk from max. 10,000 readings Block-value statistics: n, avarage x , avarage s, avarage kvar , min, max, cp, cpk; block size 3 to 100 readings |
| Data memory: |
10,000 readings in max. 500 selectable files; alphanumerical file names; stored readings and statistical values individually recallable |
| Interfaces: |
Infrared and serial RS232 interface |
| Language: |
Operator prompting and documentation in German, English, French (optional other languages) |
| Operating temperature: |
0°C to 50°C / 32°F to 122°F (storage temperature - 20°C to 60°C / -4°F to 140°F) |
| Surface temperature: |
-15°C to 60°C / 5°F to 140°F (briefly above 60°C / 140°F up to 150°C / 302°F) |
| Power supply: |
2 x round cell (AA) 1.5 V up to 60 hours of operating time |
| Housing/keypad: |
Protection class IP52 (protection against dust and dripping water) |
| Dimensions: |
Gauge: 140mm x 62mm x 30mm (5.6” x 2.5” x 1.2”) HxWxD Probe: dia. 14 mm x 83mm (dia. 0.56” x 3.3”) |
| Weight: |
approx. 200 g (7 oz) - gauge including batteries and probe |
| Standards: |
DIN EN ISO, ASTM, BS |
| Warranty: |
1 year |